The efficiency of using the stiff guidance technique in stent placement for treating the colorectal cancer obstruction

Linhui Xu1, Jianzhuang Ren1,(), Xuhua Duan1, Pengfei Chen1, Wenguang Zhang1, Li Wan1, Jiaxing Wang1, Donglin Kuang1, Fangzheng Li1, Xinwei Han1   

  1. 1. Interventional Radiology Department, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
  • Received:2019-11-04 Online:2020-06-25 Published:2020-06-25
  • Contact: Jianzhuang Ren
  • About author:
    Corresponding author: Ren Jianzhuang, Email:

Abstract:

Objective

To investigate the feasibility and clinical efficacy of rigid technique in the treatment of colorectal cancer obstruction with metal stent.

Methods

Retrospective analysis of the clinical data of 77 patients with colorectal cancer obstruction admitted from January 2014 to September 2018, record the operation time of metal stent placement using rigid guiding technique, measure the degree of abdominal circumference reduction at 24 hours postoperatively, postoperative bloating relief time, postoperative adverse reations, analysis technique success rate, clinical success rate and complications.

Results

Seventy-seven patients with colorectal cancer obstruction were implanted with 85 metal stents, with a technical success rate of 100% and an operation time of 30~240 minutes (median 50 minutes), among which six patients were implanted with two metal stents, and one patient was placed with three metal stents. The abdominal circumference of the patient before the measurement of the umbilical level was (107.8±12.1) cm, and it decreased to (83.9±8.2) cm 24 hours after surgery, and the reduction was (23.4±11.2) cm, and the postoperative relief time of abdominal distension was (1~6 days) 1.9 days. There were 62 cases (80.5%) with complete cure, nine cases (11.7%) with improvement, six cases (7.8%) without improvement, and the clinical success rate was 93.5%. Three patients (3.9%) had abdominal pain, and one (1.3%) had a small amount of blood in the stool. Surgical treatment was performed on 26 patients 5~14 days after metal stent implantation, and wound infection occurred in one patient, without complications of intestinal fistula and intestinal obstruction. The stent patency rate was 92.2% at one month, 84.7% at three months, 68.4% at six months and 46.9% at twelve months.

Conclusion

Metal stent implantation is a safe and effective treatment for colorectal cancer obstruction. Meanwhile, the rigid guidance technique can improve the technical success rate.

Key words: Colorectal neoplasms, Intestinal obstruction, Colon stent